Description
General Details | |
Model | SP-L911 |
Main Technical Data | DOL(Direct on Line) Single pump |
Start type | DOL(Direct on Line) |
Rated input voltage & output power | AC110V Single Phase 50Hz/60Hz Power: 0.75kw – 2.2kw or 1HP – 3HP Full load Max(18A), Starting Max (90A) |
Capacitor | Reserved space for one run capacitor installing from 08 μF – 120 μF |
Product function/features | Pump stalled protection Dry run protection with sensor free Under voltage protection Over voltage protection Repeat start protection Over temperature protection {“By Thermal protector & PTC Sensor”} |
Application & Control characteristic | Control and protect universal pump Adopting, liquid probe, float switch or pressure switch to control pump start and stop Applied for water supply by liquid level control through float switch or liquid probe Applied for booster by pressure control through pressure switch and pressure tank Applied for drainage by liquid level control through float switch or liquid probe |
Other features | Pump last five faults record displaying Pump accumulative running time displaying Pump shaft anti-rust Present one passive dry contact point (BA port) Present RS485 port Remote control panel(Optional) LCD screen displaying pump running status LCD screen locked function under auto state(Settable) LCD screen display dynamic real time pump running status and information Pump start and stop value can be easily set on the LCD screen Push button calibration Memory function when power off & recovery Signal transmission distance up to 1000m Pump start time delay (Time settable) Pump stop time delay (Time settable) Overflow alarm for drainage application |
Main technical data
|
-77 °F – + 131 °F 20% -90%RH, no drips concreted IP54 Wall mounting 12 x 9.4 x 5 inch |
Connectable sensors | Liquid probe (standard accessory) / Float swith / Pressure switch ” 4-20mA transmitter ” (Optional) |
Characteristic:
- Built in Function Switch For Water Transfer, Booster and Sewage Lifting (Drainage)
- Available Terminals For level Sensor, Float Switch, Pressure Switch Wiring
- Memory Function When Power off & Recovery
- LCD Screen Displays Pump Running Information
- Pump Accumulative Running Time Displaying
- IP 54 Protection Grade
- Present User Remote Monitor
- Auto / Manual
- Over Load Protection
- Under / Over Voltage Protection
- Dry Run Protection With Sensor Frees
- Push Button Calibration
- Rapid Cycle Protection
- Motor Stalled Protection
- Open Phase Protection
- Pump Shaft Rust Protection
- Pump Last Five Fault Record Displaying
- Present One Dry Contacting Point
- Three Phase Unbalance Protection
- Phase Reversal Protection
- Pump Motor Winding Over Temperature Protection
- Available RS 485 Communication Port