Description
Design Engineering
- Dual Chamber Electric Pump (Motor, Mechanical Seal).
- Oil Bath Motor (Biodegradable and Dielectric) for Colling and Bearing Lubrication.
- Sealing Ring – Engine Face.
- Oil Bath Mechanical Seal.
- Permissible Draught of Water: 16.4 ft.
- Protection Class IP 68.
- Class “F” Insulation.
- Max. Pumped Liquid Temperature: 77°F with Partially submerged pump and 95°F with Totally submerged pump.
- By Pass Section: 2″.
- Three Phase: 230V/60Hz with overload protection care of the user.
- Cable Length: 32.8 ft. H07RN-F.
Performance Curve
Model | Voltage | HP | P1 Max. | Ampere | Capacitor | Capacity | ||||||||
60Hz | Kw | A | μF | VC | Gal/Min | 0 | 13.2 | 52.8 | 92.5 | 132.1 | 171.7 | 211.3 | ||
JIGER BC 200 | 3 x 230V | 2.5 | 3.5 | 10 | – | – | Ft. | 60.7 | 57.4 | 49.2 | 39.4 | 27.9 | 18 | 6.6 |
Dimensions
Dimensions (inch) | Cable Length | Weight | |||||
A | B | C | D | E | F | Ft. | Lb |
2 NPT | 5.9 | 9.1 | 16 | 4.9 | 6.7 | 32.8 | 40.3 |